Clima 100
The Clima 100 consists of a number of high-quality controllers which enable you to automatically control your ventilation, screen and heating systems at a competitive price. The Clima 100 is available in three models:
|
 |
- Clima 100V - for ventilation control
- Clima 100S - for screen control
- Clima 100H - for heating control
Clima 100 H Heating Controller
The Clima 100 H is designed to control hot air heaters or pipe heating systems. In the latter case, the Clima 100 H is connected to the mixing valve and circulation pump by a pump and mixing valve switch (the HortiMaX OS100MP, for example). A pipe temperature sensor can be fitted using a HC-PT adapter. A safeguard ensures the pump and mixing valve is opened once every 24 hours to prevent clogging. An externally fitted time switch automatically switches between the day and night time temperature.
| Settings |
Day period heating setpoint |
| |
Night period heating setpoint |
| |
Gain: determine the adjustment of the pipe temperature if the air temperature deviates from temperature stpoint (the disired temperature). |
| |
Mixing valve run time gain: determines the run time of the mixing valve if the temperature deviates from the temperature setpoint. |
| |
Minimum pipe temperature |
| |
Maximum pipe temperature |
| Generates alarm if |
The pipe temperature falls below minimum temperature exceeds maximum temperature |
| LED indications |
Heat demand |
| |
Pipe temperature too high or too low |
| |
Night period or day period |
Clima 100 V Ventilation System
The Clima 100 V is specially designed to control one-sided or double-sided ventilation which has a central drive system. Ventilation is controlled based on the measured air temperature and the ventilation setpoint. An externally fitted time switch automatically switches between the day and night time temperature. A wind speed guard closes the vents if the wind speed exceeds the set maximum (because of a gale or storm, for example). The vents reopen as soon as the wind speed drops and the delay time expires. A rain guard, which closes the vents when rain is detected, is optional.
| Settings |
Day period ventilation setpoint |
| |
Night period ventilation setpoint |
| |
Storm level |
| |
Delay time after storm |
| |
Gain factor for setting the response speed in case of temperature |
| |
Deviation |
| |
Ventilation run time |
| Generates alarm if |
The temperature sensor is malfunctioning |
| |
Storm or rain conditions apply |
| LED indications |
Power supply present |
| |
Air temperature too high |
| |
Outside temperature too low |
Clima 100 S Screen Controller
The screen controller is used to control various types of screens.
- Shading screen (closes if radiation exceeds the set maximum)
- Energy saving screen (closes if the outside temperature falls below the set minimum)
- Blackout screen, opens or closes by means of a time switch or manual switch. The screen opens in phases to prevent "coldfall". A screen gap can be applied if the air temperature rises too high.
| Setting |
Radiation level close screen |
| |
Outside temperature close screen |
| |
Radiation limit open screen |
| |
Maximum air temperature. If the measured temperature exceeds this value, a proportional screen gap is applied.
Maximum screen gap |
| |
Screen run time |
| Generates aarm if |
Outside temperature or radiation sensor is malfunctioning |
| LED Indications |
Radiation too high |
| |
Air temperature too high |
| |
Outside temperature too low |
| |
|
| |
|
| |
|
Download the leaflet
The leaflets available on this site are in PDF format. You can view these leaflets using Acrobat Reader, which is free to download from the Adobe website. Click on the icon below to go to their website.